HDT vicat testing machine Detailed information:
HDT and vicat testing machine
KL-WK-300F Microcomputer control heat deformation, vicat tester, is to adapt to the rapid development of the plastics industry and increase the level of researching and testing of materials, using the latest international and national standards: GBT8802, ATM D601-01, ISO75- 1: 1993 "plastics - Determination of temperature of deflection under load", ISO306: 1994 "plastics - thermoplastic Vicat softening point temperature measurement", GB / T1633-2000 "thermoplastic Vicat softening point temperature measurement", GB / T1634 2004 "plastics - Determination of temperature of deflection under load" designed, which uses computer technology, operating on a WindowsXP platform, to make the product performance more stable, the operation procedures simpler. The machine, high degree of automation, is currently the most advanced detection equipment used for testing deformation and softening temperature of non-metal materials in China.
HDT vicat testing machine Function:
Real-time display test temperature and temperature - deformation curve;
HDT and vicat testing machine During the test, by entering the size of the sample, it can automatically calculate the required test load mass;
On-line temperature, deformation arbitrarily set within the range; the upper limit temperature control with automatic protection function;
Automatic error correction by software;
Test curve arbitrarily set color, real-time display and hide, width and thickness of curve conversed arbitrarily;
When the test is completed or reached the maximum temperature, the upper limit temperature control with automatic protection function, automatically alarm and automatically stop heating.
After the test is completed, print test curve and test reports. Query previous test history, and can redraw the previous test curve.
Specimen rack automatically lifting, easy to install the sample;
HDT and vicat testing machine sample holder criteria: 3
Software can do two different tests- vicat and heat deformation tests on one machine Vicat heat distortion function of;
HDT vicat testing machine Main parameters:
1, Temperature control and measurement range: room temperature -300 ℃
2, Heating rate: 120 ℃ / h (12 ± 1 ℃ / 6min)
50 ℃ / h (5 ± 0.5 ℃ / 6min)
3, The temperature resolution: 0.1 ℃, the maximum temperature error: 0.5 ℃
4, Deformation measurement: Range 0-3mm
5, The maximum error 0.01mm
6, Deformation resolution 0.001mm
7, Heat distortion test span adjustably, adjustable range of 60mm-120mm.
8, The mixing system: double stirring motors, stirring more evenly.
9, Heating medium: methyl silicone oil (low viscosity better) or transformer oil (use less than 200 ℃), 12 liters fuel tank.
10, Heating power: 4KW Power: 220V ± 10% 20A 50Hz-60 Hz
HDT vicat testing machine Configuration
1, A computer (configuration: high with a computer, including test software)
2, Host
3, Three sample holder
4, Heat deformation head: three
5, Three Vicat needles
6, Weight (including weight box) three sets(Schedule)